Indicators

Panel meter with moving-coil element

SIR3, SIQ3

Analogue indicator SIR3 / SIQ3

  • Robust glass-fibre-reinforced plastic housing, also suitable for outdoor areas; round or square design
  • Individual scale design and corporate logos possible
  • Also available with a centred zero moving-coil element (±1 mA)
  • Direct connection of the current, voltage measuring signals
  • Complies with DNV GL certification (other certifications available on request)

Description

Type SIR3, SIQ3 analogue indicators are analogue indicating instruments (gauges) and commonly used in the fields of the shipbuilding industry, transport technology, machinery and equipment. They are suitable for use in harsh ambient conditions and comply with the requirements of DIN EN 50155 for railway applications and the ship classification society DNV-GL. Thanks to its mechanical design, the casing is extremely resistant to salt spray, enabling use in outdoor applications.

Technical data

Input signal

Analogue measuring signals (current, voltage)

Operating temperature

Reference range of operation: 5 ... 35 °C, nominal range of operation: -25 ... +70 °C

Connection

8-pin connector

Mounting

Fastening screws with dovetail key and hand knob (tool-less)

Protection class

IEC 60529: Front of housing IP66, IP67 and IP68 (1m, 24h); rear of housing IP30 (standard, higher on request)

Approvals

DNV-GL (other certifications available on request)

Ordering information

Structure of type code SIR3…, SIQ3…

SI

R

3

-060

-I2

-123

Example: SIR3-060-I2-1234

Housing type

 

Series

 

Housing size

 

Input signal

 

Scale version

Type code SIR3…, SIQ3…

Housing type

R

Round

 

Q

Square

 

Series

 

3

Fixed digit (indicator generation)

 

Housing size

 

-072

Square, front frame size 72 x 72 mm

 

-096

Square, front frame size 96 x 96 mm

 

-144

Square, front frame size 144 x 144 mm

 

-060

Round, housing diameter Ø 60 mm

 

-080

Round, housing diameter Ø 80 mm

 

-100

Round, housing diameter Ø 100 mm

 

-130

Round, housing diameter Ø 130 mm

 

Input signal

 

-I1

Direct current 0…20 mA

 

-I2

Direct current 4…20 mA

 

-I4

Direct current -20…0...+20 mA

 

-I0

Direct current, customer-specific compensation

 

-U1

DC voltage, 0 ... 10 VDC

 

-U2

DC voltage, 2 ... 10 VDC

 

-U4

DC voltage, -10…0…+10 VDC

 

-U0

DC voltage, customer-specific compensation

 

-UG0

DC voltage, compensation for GE1214 tachometer

 

-W0

Customised alternating voltage measuring range

 

Scale version

 

-1234

Measuring range, scale graduations etc.

 

Customised
indicator

-V567

Customised indicator

 

SI

_

3

-_ _ _

-_ _

Example: SIQ3-096-U2-1234

Ordering information

  • To ensure the dial design is implemented as accurately as possible, exact descriptions, drawings or photos of existing dials should accompany the order.
  • If the dial markings are not specified when ordering, coarse/fine scale graduations will be supplied as standard. An orientation graduation or other deviating dial markings must be specified in the order.
  • The dial version number and the V### number are assigned by NORIS.