Non-contact multi-channel speed sensor type, Hall effect, stainless steel

FAHU52

FAH52

  • Particularly suitable for transport technology due to its design and type testing in accordance with EN 50155
  • Scanning of all electrically conductive materials (steel or aluminium)
  • With voltage or current output signal
  • With up to 4 galvanically isolated sensors in one enclosure
  • Robust and high quality housing: IP69 pressure-tight and individually tested at 5 bar (for details see technical data)
  • Straight or lateral conductor outlet, available with conductor protection system

Description

Speed sensors of type FA52 are non-contacting multi-channel speed encoders with a stainless-steel flange and sensor tube. They measure frequency in accordance with the eddy-current or difference-hall-effect principle. They acquire the speed of ferromagnetic (FAH type) or electrically conductive (FAW type) gearwheels, e. g. gearwheels with various tooth shapes, screw heads, drill holes, apertures, grooves or pulse bands on smooth shafts (accessories). Their compact and robust design, as well as the relevant tests as per DIN EN 50155, make them ideal for applications in the field of transport technology, e. g. measuring speed at the traction motor, gearbox or wheelset. The sensors are available with different output signals (voltage or current output).

Typ

Measuring principle

Signal outputs

Signal form

FAHU52[..]-U01

Hall

Four galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted
Type –U01: voltage output
Type –U11: current output

FAHU52[..]-U11

FAHU52[..]-U02

Hall

Two square wave signals + two galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted
Type –U02: voltage output
Type –U12: current output

FAHU52[..]-U12

FAHU52[..]-U03

Hall

Two galvanically isolated measuring systems, each with two square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted
Type –U03: voltage output
Type –U13: current output

FAHU52[..]-U13

FAHU52[..]-U21

Hall

Four galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted
Q1, Q2 with voltage output
Q3, Q4 with current output

FAHU52[..]-U22

Hall

Two square wave signals + two galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted
Q1, Q2 with voltage output
Q3, Q4 with current output

FAHU52[..]-U23

Hall

Two square wave signals + two galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted
Q1, Q2 with current output
Q3, Q4 with voltage output

FAHU52[..]-U24

Hall

Two galvanically isolated measuring systems, each with two square wave signals, Q1 to Q2 and Q3 to Q4 are 90° phase shifted
Q1, Q2 with voltage output
Q3, Q4 with current output

Technical data

Supply voltage

9 ... 32 VDC

Frequency range

0 ... 25,000 Hz

Measuring channels

Up to four galvanically isolated measuring channels with voltage or current output signal

Output signal and signal type

4 square wave signals

Scanning object

Ferromagnetic materials

Scanning object - distance

0.2 ... 3 mm; recommended: 1.0 ± 0.5 mm

Operating temperature

-40 ... +120 °C

Protection class

Housing: IP66/IP68/IP69

Ordering Information

Type code structure

FA

H

U

52-

11-

S

X

07-

M30-

S0-

U01

Example: FAHU52-11-SX07-S0-U01

Measuring principle

 

Measuring principle supplement

 

Construction type and material

 

Nominal length L1 of the sensor tube

 

Connection outlet

 

Electrical connection

 

Cable length

 

Module

 

Shield

 

Signal variant

Type code FAHU52

Measuring principle

H

Difference-Hall

Measuring principle
supplement

 

U

4 output signals, galvanically isolated

Construction type and material

 

52-

Flange, stainless steel sensor tube

Nominal length

 

11-

L1 = 29 mm

Connection outlet

 

 

Without code: straight cable outlet

S

Lateral cable outlet

Electrical connection

 

X

Cable end standard (without protective tubing)

XGS

Cable end, protective tubing, steel reinforced

XGT

Cable end, protective tubing, textile reinforced

XP

Cable end, protective tubing, polyamide

Sheath length

 

05-

Sheath length 2.0 m, halogen-free

07-

Sheath length 5.0 m, halogen-free

08-

Sheath length 7.5 m, halogen-free

09-

Sheath length 10.0 m, halogen-free

Module

 

M10-

Module m1

M12-

Module m1.25

M15-

Module m1.5

 

Without code: Module m2

M25-

Module m2.5

M30-

Module m3

Shield

 

 

Without code: Shield attached to the sensor housing

S0-

Shield not attached to the sensor housing

Signal variants

Uxx

Output signal variants (xx see next table)

FA

_ _

_ _

_ _-

_ _-

_ _

_ _

_ _-

_ _-

_ _-

_ _

Example:
FAHU52-11-X07-U01

Customer-specific types

If you don’t find anything suitable among our standard types, we’ll be happy to develop a tailored solution with you to meet your requirements (-P types). They also meet the abovementioned standards thanks to our type-approved modular kits.

Code

Output signals variant

U01

Four galvanically isolated output signals (voltage)

U11

Four galvanically isolated output signals (current)

U02

Two output signals + two galvanically isolated output signals (voltage)

U12

Two output signals + two galvanically isolated output signals (current)

U03

Two galvanically isolated measuring systems, each with two output signals (voltage)

U13

Two galvanically isolated measuring systems, each with two output signals (current)

U21

Four galvanically isolated output signals (Q1, Q2 voltage; Q3, Q4 current)

U22

Two output signals + two galvanically isolated output signals (Q1, Q2 voltage; Q3, Q4 current)

U23

Two output signals + two galvanically isolated output signals (Q1, Q2 current; Q3, Q4 voltage)

U24

Two galvanically isolated measuring systems, each with two output signals (Q1, Q2 voltage; Q3, Q4 current)