Search

N3000-SAP

Das Bild zeigt einen Tanker mit Containern beladen auf hoher, tiefblauer See mit blauem Himmel und einem Wolenstreifen am Horizont

N3000-SAP

N3000-SAP

  • Safety system for engine emergency shut-down

  • Compact and robust construction for applications directly on engines

  • Large number of preprogrammed engine types

  • All inputs are monitored for wire breaks

  • All connections are plug-in for easy installation

  • Ideal for use in shipbuilding thanks to approvals from classification societies

The safety system N3000-SAP has been developed for electrically monitoring the basic operating parameters of a combustion engine. It is the central unit for triggering an emergency shut-down of the engine to avoid damage. Thanks to its compact and robust design, it is particularly suitable for use on ships, directly on combustion engines. Signal processing with the safety system is purely digital. Together with fast, crystal-accurate speed acquisition, it ensures maximum safety and system reliability.

Type

Signal panel for installation in control cabinets and operating panels

Operating voltage UB

18 … 73 VDC

Operating temperature

-25 … +70°C

Power Consumption

< 10W ±10%

Operating Temperature

-25°C … +70°C

Storage Temperature

-40°C … +100°C

Relative Humidity

According to IEC60068-2-30 Db ≤ 96% @ 55°C

Vibration Resistance

According to IEC60068-2-6 Fc

Shock Resistance

According to IEC60068

Electromagnetic immunity

According to IEC 61000-4 and IEC 60553

Electromagnetic emissions

According to CISPR 16-1– EMC2

Connections

4 x inputs for manual emergency stop
5 x inputs for automatic stop
2 x pick-up inputs for non-contacting speed acquisition
2 x inputs for overriding the automatic stop channels with channel assignment as per the requirements of the various classes
1 x input for remote reset of the automatic stop channels
2 x outputs for shut-down valves, monitored for wire breaks
4 x outputs for individual signalling of automatic stop channels 1 to 4
2 x outputs for collective signalling of emergency stop
2 x outputs for collective signalling of automatic stop
2 x outputs for signalling of overspeed stop
2 x outputs for system fault messages, emergency stop
2 x outputs for system fault messages, automatic stop
2 x outputs for system fault messages, overspeed stop
2 x outputs for speed frequency (potential free)
2 x analogue outputs for speed 4 ... 20 mA / 0 ... 10 V

Terminal type

Plug-in terminals, wire cross-section ≤ 2.5mm²

Switching Capacity of Outputs

Shutdown Outputs with I < 2 A @ 24 VDC
Signal Outputs with I < 0.5 A @ 24 VDC

Analog Out 4 … 20 mA

Load Resistance RL ≤ 600 Ω

Analog Out 0 … 10 V

Load Current IL ≤ 20 mA

Wire-Cable monitoring

Full wire break and short circuit detection

Protection Class

IP65 when installed

User interface material

Laminated aluminum

Housing

Stainless steel

Front panel dimensions

L: 250mm, W: 140mm, D: 4mm

Housing

L: 222mm, W: 110mm, D: approx. 57mm without cable space

Weight

Approx.1.4 kg

Applied Standards

IEC61000-6-2; IEC61000-6-4; IACS UR E10 Rev8