Search

VTK5

VTK5

VTK5

  • Measuring transducer for temperature, thermocouple

  • Simple application; for harsh environments

  • Compact design for mounting side by side

  • Fine adjustment of the measuring range via sealed integrated trimming potentiometer

  • Operating status indication via integrated LED

Measuring transducers of type VTK5 convert signals from a thermocouple into standardised output signals. They are mounted on G rails or top-hat rails. The sensor input and supply voltage for the output signal are galvanically isolated. Its compact and robust design, as well as the relevant shipbuilding approvals, make this product ideal for marine applications.

Supply voltage UB

9...32 VDC

Input signal

Thermocouples type K (NiCr-Ni) according to EN60584-1

Output signal

0 ... 10 V/DC (VTK5..-G1), 2 ... 10 V/DC (VTK5..-G2) short-circuit proof, load current max.20 mA; 0 ... 20 mA (VTK5..-I1), 4 ... 20 mA (VTK5..-I2), max. load resistance 500 Ω

Operating temperature

-20°C ... +70°C

Connection

DIN EN 46244 tab connector, gold-plated A6,3 x 0.8

Mounting

TS32 G-rail or TS35 top hat rail

Part code structure

VTK5

1

-I2

Example: VTK58-I2

Input signal

Output signal

Part code VTK5 ...

Input signal

8

0 … 600°C = 0 … 24.902 mV

9

0 … 800°C = 0 … 33.277 mV

Output signal

-G1-

Output 0 … 10 V DC, short-circuit proof

-G2-

Output 2 … 10 V DC, short-circuit proof

-I1-

Output 0 … 20 mA

-I2

Output 4 … 20 mA

VTK5

__

-__

Example: VTK58-I2