  • Typical applications: Rail Technology (Light & Heavy Rail) and Special Machinery (Mining)

  • Frequency measurement with ferromagnetic scan objects using the Hall-effect principle

  • Lifecycle-cost optimised: Wear- and maintenance-free due to non-contact scanning, high durability due to robust design

  • Robust design for risk-free installation and extreme environmental conditions

  • Well-suited for safety applications, e.g., fire protection according to EN 45545

  • Up to 4 measuring channels can be galvanically isolated in a single housing. Voltage signals or current output signals can be featured in any combination.

Type FAHU52 speed sensors are non-contacting three- or four-channel speed sensors with a stainless-steel flange and sensor tube. They measure frequency in accordance with the Hall-effect principle. They acquire the speed of ferromagnetic objects, e.g., toothed wheels with various tooth shapes, screw heads, bore holes, apertures, grooves or pulse bands on smooth shafts (accessories). Their compact and robust design, as well as the relevant tests as per DIN EN 50155, make them ideal for applications in the field of transport technology, e.g., measuring speed at the traction motor, gearbox or wheel set. The sensors are available with different output signals (voltage or current output).

Type

Signal outputs

Signal form

FAHU52[..]-U01

Four galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 phase shift by 90°

Type –U01: Voltage outputType –U11: Current output

/fileadmin/cms_upload/en/resource/png/27021598142752395.png

FAHU52[..]-U11

FAHU52[..]-U02

Two square wave signals + two galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 phase shift by 90°

Type –U02: Voltage outputType –U12: Current output

/fileadmin/cms_upload/en/resource/png/27021598142845451.png

FAHU52[..]-U12

FAHU52[..]-U03

Two galvanically isolated measuring systems each with two square wave signals, Q1 to Q2 and Q3 to Q4 phase shift by 90°

Type –U03: Voltage outputType –U13: Current output

/fileadmin/cms_upload/en/resource/png/27021598142855947.png

FAHU52[..]-U13

FAHU52[..]-U21

Four galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 phase shift by 90°

Q1, Q2 with voltage outputQ3, Q4 with current output

/fileadmin/cms_upload/en/resource/png/27021598142752395.png

FAHU52[..]-U22

Two square wave signals + two galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 phase shift by 90°

Q1, Q2 with voltage outputQ3, Q4 with current output

/fileadmin/cms_upload/en/resource/png/27021598142845451.png

FAHU52[..]-U23

Two square wave signals + two galvanically isolated square wave signals, Q1 to Q2 and Q3 to Q4 phase shift by 90°

Q1, Q2 with current outputQ3, Q4 with voltage output

/fileadmin/cms_upload/en/resource/png/27021598142845451.png

FAHU52[..]-U24

Two galvanically isolated measuring systems each with two square wave signals, Q1 to Q2 and Q3 to Q4 phase shift by 90°

Q1, Q2 with voltage outputQ3, Q4 with current output

/fileadmin/cms_upload/en/resource/png/27021598142855947.png

Supply voltage UB

9 ... 32 V DC

Frequency range

Difference-Hall principle:0 Hz ... 25,000 Hz

Measuring channels

1 or 2 measuring channel

Output signal

Depending on the sensor type:2 square wave signals or2 square wave signals and 1 status signal (direction of rotation or standstill) or2 square wave signals + 2 inverted square wave signals

Scan object

Ferromagnetic materials

Air gap

Permitted: 0.2 mm ... 3 mm

Operating temperature

-40 °C … +120 °C Variants with current output: -40 °C … +120 °C

Degree of protection

Housing: IP66/IP68/IP69

Part code structure

FA

HU

52 -

11 -

S

XV

05 - 

M10

U01

Example: FAHU52 - 11 - SXV05 - M10U01

Type

 

 

Design and material

 

 

Nominal length

 

 

Connection outlet

 

 

Connection

 

 

Connection length

 

Addition

Type

HU

4 output signals, galvanically isolated

Design and material

52

Flange, stainless steel sensor tube

Nominal length

11

L1 = 29 mm

Connection outlet

 

Without code: straight cable outlet

S

Lateral cable outlet

Connection

Cable

XV

Cable with reinforced cable sheath

XP

Cable with corrugated conduit

XGT

Cable with protective tubing, textile reinforced

Connection length*

05

Length 2.0 m

07

Length 5.0 m

09

Length 10.0 m

Addition

M10

Module m1

M12

Module m1.25

M15

Module m1.5

 

Without code: Modul m2

M25

Module m2.5

M30

Module m3

 

Without code: shield attached to the sensor housing

S0

Shield not attached to the sensor housing

Uxx

Output signal variants (xx see table below)

FA

_

_ _-

_ _-

_

_ _

_ _-

_ _

Example: FAHU52-11-X07-U01

*Length specification applies for X, XV to the sheath of the cable, for XP, XGT to corrugated conduit or protective hose.

If you don’t find anything suitable among our standard types, we’ll be happy to develop a tailored solution with you to meet your requirements (-P types). They also meet the abovementioned standards thanks to our type-approved modular kits.

Code

Output signal variant

U01

Four galvanically isolated output signals (voltage)

U11

Four galvanically isolated output signals (current)

U02

Two output signals + two galvanically isolated output signals (voltage)

U12

Two output signals + two galvanically isolated output signals (current)

U03

Two galvanically isolated measuring systems, each with two output signals (voltage)

U13

Two galvanically isolated measuring systems, each with two output signals (current)

U21

Four galvanically isolated output signals (Q1, Q2 voltage; Q3, Q4 current)

U22

Two output signals + two galvanically isolated output signals (Q1, Q2 voltage; Q3, Q4 current)

U23

Two output signals + two galvanically isolated output signals (Q1, Q2 current; Q3, Q4 voltage)

U24

Two galvanically isolated measuring systems, each with two output signals (Q1, Q2 voltage; Q3, Q4 current)