FAH13
1-/2-channel speed sensor with stainless steel screw-in thread, Hall

  • Typical applications: Shipbuilding industry, Rail technology, Power engineering, Engine construction

  • Thread sizes (including custom threads) adapted to customer requirements

  • Very high immunity to electromagnetic interference (EMI)

  • Additional status signal for direction detection

  • Additional status signal for direction detection

Speed sensors of type FAH13 are non-contacting 1-/2-channel speed sensor with a stainless steel threaded tube. They measure frequency in accordance with the Hall-effect principle.

Type

Signal output

Signal waveform

H

1 square wave signal as voltage output

/fileadmin/cms_upload/en/resource/png/45035996422547851.png

HJ

1 square wave signal as current output

HY

1 square wave signal + 1 inverted square wave signalas voltage output

/fileadmin/cms_upload/en/resource/png/768484235.png

HZ

2 square wave signals as voltage output Q2 to Q1 phase shift by 90°

/fileadmin/cms_upload/en/resource/png/36028797143651595.png

HD

2 square wave signalsas voltage outputQ2 to Q1 phase shift by 90°outputs galvanically isolated

/fileadmin/cms_upload/en/resource/png/54043195664894859.png

HI

2 square wave signals as current outputQ2 to Q1 phase shift by 90°outputs galvanically isolated

HQ

2 square wave signals + 2 inverted square wave signalsas voltage outputQ2 to Q1 phase shift by 90°

/fileadmin/cms_upload/en/resource/png/45035996398755211.png

HR

2 square wave signals + 2 inverted square wave signalsas voltage output Q2 to Q1 phase shift by 90°outputs galvanically isolated

/fileadmin/cms_upload/en/resource/png/684047499.png

HS

1 or 2 square wave signalsas voltage outputQ2 to Q1 phase shift by 90°

and a status signal:

- as direction of rotation signal DR or

- as standstill signal SS

/fileadmin/cms_upload/en/resource/png/698689163.png/fileadmin/cms_upload/en/resource/png/18014399085053579.png/fileadmin/cms_upload/en/resource/png/18014399103305355.png

Approvals

/fileadmin/cms_upload/en/resource/png/36028797037937547.png

/fileadmin/cms_upload/en/resource/png/36028797037940363.png

/fileadmin/cms_upload/en/resource/png/45035996523602187.png

/fileadmin/cms_upload/en/resource/png/36028797037965579.png

Technical Specifications

Frequency range

0 Hz ... 20,000 Hz

Signal type

Square wave signal as voltage or current output

Measuring channels

1 or 2 measuring channels

Output signal

1 square wave signal or 2 square wave signals or square wave signal and inverted signal orsquare wave signal and status signal (direction of rotation or standstill)

Degree of protection

IP65, IP67

Hazard level

HL1 ... HL3

Material

Stainless steel

Mounting

Screw-in thread: M12x1 ... M18x1.5; 5/8"-18UNF

Part code structure

FA

HZ

13-

02

15-

X

03-

M10

Example: FAHZ13-0215-X03-M10

Type

Design & material

Nominal length

Thread

Connection

Addition

Type

H

1 Output signal (voltage)

HJ

1 Output signal (current)

HZ

2 Output signals (voltage)

HD

2 Output signal (voltage), galvanically isolated

HI

2 Output signal (current), galvanically isolated

HQ

2 + 2 Output signals (voltage), signal and inverted signal

HR

2 + 2 Output signals (voltage), signal and inverted signal, galvanically isolated

HS

1 or 2 output signals (voltage) and one status signal (DR or SS)

Design

13-

Threaded tube: Stainless steel

Nominal length

02

L1 = 60 mm, L2 = 5 mm

03

L1 = 80 mm, L2 = 5 mm

04

L1 = 100 mm, L2 = 20 mm

05

L1 = 120 mm, L2 = 40 mm

19

L1 = 50 mm, L2 = 5 mm

Lengths up to 200 mm on request

Thread

12-

M12 x 1

13-

M14 x 1

22-

M16 x 1.5

15-

M18 x 1

23-

M18 x 1.5

88-

5/8‘‘ – 18UNF

Connection

A-

Rectangular connector according to EN 175301

C-

Circular connector 14S-5P according to VG 95234

C3-

Circular connector 10SL-3P according to MIL 5015

E-

Circular connector M12x1 according to EN 61076

X-

Cable

XP-

Cable with corrugated conduit

X##°

05-

Length 2.0 m

X##°

07-

Length 5.0 m

X##°

09-

Length 10.0 m

Addition

No identifier: Module m2

M10

Module m1

M15

Module m1.5

M25

Module m2.5

M30

Module m3

No identifier: Shield connected to sensor housing

S0

Shield NOT connected to sensor housing

FA

_

_ _-

_ _

_ _-

_ _-

_ _

_ _

Example: FAHZ13-0323-A-M12S0

° Length specification applies for X to the sheath of the cable, for XP to the corrugated conduit.

If you don’t find anything suitable among our standard types, we’ll be happy to develop a tailored solution with you to meet your requirements (-P types). They also meet the abovementioned standards thanks to our type-approved modular kits.