Speed sensors

Non-contacting two-channel speed sensor with stainless steel threaded tube, difference-Hall or inductive-magnetic principle

FA13

FA13

  • Due to its design and its approvals especially suitable for shipbuilding industry
  • Speed sensor with square wave output signal
  • High quality and robust stainless steel housing: IP66/68/69
  • Excellent vibration and shock resistance
  • High degree of EMC immunity for difficult electrical environment
  • Variable lengths, threads and electrical connections
  • Optionally with two galvanically isolated output signals
  • Optionally with additional status signal for direction of rotation detection

Description

Speed sensors of type FA13 are non-contacting one- or two-channel speed encoders with a stainless steel threaded tube. They measure frequency in accordance with the difference-hall-effect principle (FAH type) or inductive-magnetic principle (FAJ type). These speed sensors are suitable for scanning ferromagnetic materials, e.g. gearwheels with various tooth shapes, screw heads, drill holes, apertures, grooves or pulse bands on smooth shafts (accessories). Its compact and robust design, as well as the relevant shipbuilding approvals, make this product ideal for marine applications.

Type

Measuring principle

Signal outputs

Signal form

FAH13

Difference-Hall

One square wave signal

FAJ13

Induct.-magnetic

One square wave signal

FAHZ13

Difference-Hall

Two square wave signals,
Q2 to Q1 is 90° phase shifted

FAHS13

Difference-Hall

Two square wave signals,
Q2 to Q1 is 90° phase shifted,
one rotation direction signal

FAHD13

Difference-Hall

Two square wave signals,
galvanically isolated,
Q2 to Q1 is 90° phase shifted

FAHQ13

Difference-hall

Two + Two inverted square wave signals, Q1 to Q2 and Q1_N to Q2_N are 90° phase shift

Approvals

 

FAH13

FAJ13

FAHZ13

FAHS13

FAHD13

FAHQ13

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

Technical Data

Supply voltage UB

9 ... 32 VDC

Frequency range

Type FAH13: 0.2 ... 20,000 Hz
Type FAJ13: 5 … 10.000 Hz

Measuring channels

Depending on sensor type:
1 measuring channel
2 measuring channels
2 galvanically isolated measuring channels
2 measuring channels and status channel for rotation direction detection

Output signal and signal type

Depending on sensor type, see description

Scanning object

Ferromagnetic materials
Read datasheet for further information

Scanning object - distance

Type FAH13: 0.2 ... 3 mm; recommended: 1.0 ± 0.5 mm
Type FAJ13: see datasheet

Operating temperature

-40 ... +120 °C

Protection class

Housing: IP66/IP68/IP69

List with available female connectors

Connector

Drawing No.

Order No.

Female connector DIN 43650-A

ZL-3A

311046

Female connector according VG95234

ZL4-1A-E

314015

Female connector Euro M12x1, shielded, straight with 2.0 m cable

ZL4-2A

522101

Female connector Euro M12x1, shielded, straight with 5.0 m cable

ZL4-2A

522102

Female connector Euro M12x1, shielded, straight with 10.0 m cable

ZL4-2A

522109

Female connector Euro M12x1, shielded, angled 90°, with 2.0 m cable

ZL4-2A

522439

Female connector Euro M12x1, shielded, angled 90°, with 5.0 m cable

ZL4-2A

522438

Female connector Euro M12x1, shielded, angled 90°, with 10.0 m cable

ZL4-2A

522437

Ordering information

Type code structure

FA

H

Z

13-

02

15-

X03-

M10-

S0

Example: FAHZ13-0215-X03-M10-S0

Measuring principle

 

Measuring principle supplement

 

Construction type & material

 

Nominal length L1 and L2 of the sensor tube

 

Thread type

 

Electrical connection

 

Module version

 

Shield

Type code FAH13[..]

Measuring principle

H

Difference-Hall

Measuring principle supplement

 

 

Without code: 1 output signal

Z

2 output signal, galvanically connected

S

2 output signals, galvanically connected with
status output (e. g. rotation direction detection)

D

2 output signals, galvanically isolated

Q

4 output signals (2 + 2 inverted)

Construction type & material

 

13 -

Sensor tube: Stainless steel

Nominal length

 

02

L1 = 60 mm, L2 = 5 mm

03

L1 = 80 mm, L2 = 5 mm

04

L1 = 100 mm, L2 = 20 mm

05

L1 = 120 mm, L2 = 40 mm

 

Other lengths up to 200 mm available on request

Thread type

 

13-

M14 x 1 (FAH13 only)

22-

M16 x 1.5 (FAH13 only)

15-

M18 x 1

23-

M18 x 1.5

88-

5/8‘‘ – 18 UNF (FAH13 only)

Electrical
connection

 

A-

DIN43650-A pin connector (FAH13 only)

C-

MIL 14-5PN VG95234 pin connector (FAH13 only)

E-

Euro M12x1 pin connector (FAH13 only, on request for FAHZ13)

H1-

DIN72585 Bayonet (FAH13 only)

X03-

Cable end with sheath length 0.5 m

X05-

Cable end with sheath length 2.0 m

X06-

Cable end with sheath length 3.0 m

X07-

Cable end with sheath length 5.0 m

X08-

Cable end with sheath length 7.5 m

X09-

Cable end with sheath length 10.0 m

Module
(for FAHD, FAHZ, FAHS, FAHQ Series)

 

M10-

Module m1

M12-

Module m1.25

M15-

Module m1.5

 

Without code: Module m2

M25-

Module m2.5

M30-

Module m3

Shield

 

 

Without code: Shield attached to the sensor housing

S0

Shield not attached to the sensor housing

FA

_ _

_ _

_ _-

_ _

_ _-

_ _-

_ _-

_ _

Example: FAHZ13-0323-X03-M12-S0

Type code FAJ13[..]

Measuring principle

J

Inductive-magnetic

Measuring principle supplement

 

 

Without code: 1 output signal

Construction type & material

 

13-

Sensor tube: Stainless steel

Nominal length

 

02

L1 = 60 mm, L2 = 5 mm

03

L1 = 80 mm, L2 = 5 mm

04

L1 = 100 mm, L2 = 20 mm

05

L1 = 120 mm, L2 = 40 mm

 

Other lengths up to 200 mm available on request

Thread type

 

13-

M14 x 1

22-

M16 x 1.5

15-

M18 x 1

23-

M18 x 1.5

88-

5/8‘‘ – 18 UNF

Electrical
connection

 

A-

DIN43650-A pin connector

C-

MIL 14-5PN VG95234 pin connector

E-

Euro M12x1 pin connector

H1-

DIN72585 Bayonet

X03-

Cable end with sheath length 0.5 m

X05-

Cable end with sheath length 2.0 m

X06-

Cable end with sheath length 3.0 m

X07-

Cable end with sheath length 5.0 m

X08-

Cable end with sheath length 7.5 m

X09-

Cable end with sheath length 10.0 m

Shield

 

 

Without code: Shield attached to the sensor housing

S0

Shield not attached to the sensor housing

FA

_ _

_ _

_ _-

_ _

_ _-

_ _-

_ _

Example: FAJ13-0323-E-S0

Customer-specific types

If you don’t find anything suitable among our standard types, we’ll be happy to develop a tailored solution with you to meet your requirements (-P types). They also meet the abovementioned standards thanks to our type-approved modular kits.