Description

Measuring transducers of type VTK5 convert signals from a thermocouple into standardised output signals. They are mounted on G rails or top-hat rails. The sensor input and supply voltage for the output signal are galvanically isolated. Its compact and robust design, as well as the relevant shipbuilding approvals, make this product ideal for marine applications.

Technical data

Supply voltage Us

9...32 VDC

Input signal

Thermocouples type K (NiCr-Ni) according to EN60584-1

Output signal

0 ... 10 V/DC (VTK5..-G1), 2 ... 10 V/DC (VTK5..-G2) short-circuit-proof, load current 20 mA max.; 0 ... 20 mA (VTK5..-I1), 4 ... 20 mA (VTK5..-I2), load resistance 500 Ω max.

Operating temperature

-20 °C ... +70 °C

Connection

DIN EN 46244 gold-plated tab connector A6.3 x 0.8

Mounting

TS32 G-rail or TS35 top-hat rail

Ordering information

Type code structure

VTK5

1

-I2

Example: VTK58-I2

Input signal

 

Output signal

Type code VTK5 …

Input signal

8

0 … 600 °C = 0 … 24.902 mV

 

9

0 … 800 °C = 0 … 33.277 mV

 

Output signal

 

-G1-

Output 0 … 10 V DC, short-circuit proof

 

-G2-

Output 2 … 10 V DC, short-circuit proof

 

-I1-

Output 0 … 20 mA

 

-I2

Output 4 … 20 mA

 

VTK5

__

-__

Example: VTK58-I2