Limit value switch for frequency (direct voltage)
Limit value switches of type RG5 monitor electrical measured variables. The integrated relay switches when the actual value present reaches the set target value. Open-circuit devices can also be equipped with a self-latching feature as an option. Furthermore, limit value switches of this type are equipped with sensor monitoring for short circuits and wire breaks. Its compact and robust design, as well as the relevant shipbuilding approvals, make this product ideal for marine applications.
Supply voltage US Us | 9 ... 32 VDC |
Input signal | Frequency, DC voltage |
Output contact | Potential-free normally open contact or normally closed contact, closed circuit or open circuit |
Maximum switching capacity | 30 W (1 A at 30 VDC; 0.5 A at 60 VDC); 40 W (0.2 A at 220 VAC) |
Operating temperature | -20 °C ... +70 °C |
Connection | DIN 46244 fl at connector, gold-plated A6.3 x 0.8 |
Mounting | Snap-fit on G-channel TS32 or top-hat channel TS35 |
Type code structure | |||
---|---|---|---|
RG5 | 1 | -A | Example: RG51-A |
Input range | |||
| Output signal |
Type code RG5 … | ||||
---|---|---|---|---|
Input range | 1 | 0 … 10 V DC |
| |
2 | 2 … 10 V DC |
| ||
Output contact |
|
| Output contact as changeover switch in normally closed |
|
A | Output contact as changeover switch in normally open |
| ||
S | Output contact as changeover switch in normally open with test function and self-latching feature |
| ||
RG5 | __ | -__ | Example: RG51-A |